Skip to content
Ohm Bands

1.87 Ω resistor colour code

Five bands: Brown · Grey · Violet · Silver · Brown. The first three give the digits — a precision value needs all three — then the multiplier, then how far off the real part may be.

187×0.01±1%
Brown1Grey8Violet7Silver×0.01Brown±1%

Nominal

1.87 Ω

1.87 ohms

Real range at ±1%

1.8513 Ω – 1.8887 Ω

A brown band allows this much drift.

Series

E96

A 1% precision value. Five bands, not four.


Band by band

BandColourMeaning
1Brown1st digit — 1
2Grey2nd digit — 8
3Violet3rd digit — 7
4SilverMultiplier — ×0.01
5BrownTolerance — ±1%

How much it can take

Current and dissipation across the resistor, and the package you need. The suggested rating keeps a factor of two in hand, which is what anyone building a board actually does.

Across itCurrentDissipatedPackage to pick
3.3 V1.76 A5.82 Wno standard part — needs a power resistor or a heatsink
5 V2.67 A13.4 Wno standard part — needs a power resistor or a heatsink
12 V6.42 A77 Wno standard part — needs a power resistor or a heatsink
24 V12.8 A308 Wno standard part — needs a power resistor or a heatsink

What you can actually get

Parts made

11

861st most of 1,465 values

In stock

0

across 0 of them

Cheapest at 100

$0.01

each

Tolerances sold

±1%

Packages: 0805, 1210, 1206, 0603, 0402, 1218, 0201. Ratings: 50mW to 1W.

Assembly stock from the JLCPCB library, read 2026-09-24. That is what a board house will place for you — not everything a distributor sells.

The same value, marked differently

Surface mount

1R9· three-digit, nearest only

1R87· four-digit, precision parts

27A· EIA-96, for the smallest parts

Three digits carry two significant figures, so they cannot write 1.87 Ω — 1R9 means 1.9 Ω. A part at this value is marked 1R87.

If you only have E24

BrownGreyGoldGold

1.8 Ω is the nearest four-band value — -3.7% off.

Values that can overlap this one

At ±1% the tolerance bands of neighbouring values run into each other. A part sold as one of these could measure the same as a 1.87 Ω — which is why measuring beats reading when it matters.

If you do not have one

Standard values that land within 1% of 1.87 Ω when combined.